| <!doctype html> |
| <title>WebSockets : Boundary-value tests for the 'Extended payload length' field in RFC6455 section5.2 'Base Framing Protocol'</title> |
| <meta name=timeout content=long> |
| <script src=/resources/testharness.js></script> |
| <script src=/resources/testharnessreport.js></script> |
| <script src=constants.sub.js></script> |
| <meta name="variant" content=""> |
| <meta name="variant" content="?wss"> |
| <meta name="variant" content="?wpt_flags=h2"> |
| <div id=log></div> |
| <script> |
| async_test(function(t){ |
| var ws = new WebSocket(SCHEME_DOMAIN_PORT+'/echo'); |
| var datasize = 125; |
| var data = null; |
| ws.onopen = t.step_func(function(e) { |
| data = new Array(datasize + 1).join('a'); |
| ws.send(data); |
| }); |
| ws.onmessage = t.step_func(function(e) { |
| assert_equals(e.data, data); |
| t.done(); |
| }); |
| ws.onclose = t.unreached_func('close event should not fire'); |
| }, "Application data is 125 byte which means any 'Extended payload length' field isn't used at all."); |
| |
| async_test(function(t){ |
| var ws = new WebSocket(SCHEME_DOMAIN_PORT+'/echo'); |
| var datasize = 126; |
| var data = null; |
| ws.onopen = t.step_func(function(e) { |
| data = new Array(datasize + 1).join('a'); |
| ws.send(data); |
| }); |
| ws.onmessage = t.step_func(function(e) { |
| assert_equals(e.data, data); |
| t.done(); |
| }); |
| ws.onclose = t.unreached_func('close event should not fire'); |
| }, "Application data is 126 byte which starts to use the 16 bit 'Extended payload length' field."); |
| |
| async_test(function(t){ |
| var ws = new WebSocket(SCHEME_DOMAIN_PORT+'/echo'); |
| var datasize = 0xFFFF; |
| var data = null; |
| ws.onopen = t.step_func(function(e) { |
| data = new Array(datasize + 1).join('a'); |
| ws.send(data); |
| }); |
| ws.onmessage = t.step_func(function(e) { |
| assert_equals(e.data, data); |
| t.done(); |
| }); |
| ws.onclose = t.unreached_func('close event should not fire'); |
| }, "Application data is 0xFFFF byte which means the upper bound of the 16 bit 'Extended payload length' field."); |
| |
| async_test(function(t){ |
| var ws = new WebSocket(SCHEME_DOMAIN_PORT+'/echo'); |
| var datasize = 0xFFFF + 1; |
| var data = null; |
| ws.onopen = t.step_func(function(e) { |
| data = new Array(datasize + 1).join('a'); |
| ws.send(data); |
| }); |
| ws.onmessage = t.step_func(function(e) { |
| assert_equals(e.data, data); |
| t.done(); |
| }); |
| ws.onclose = t.unreached_func('close event should not fire'); |
| }, "Application data is (0xFFFF + 1) byte which starts to use the 64 bit 'Extended payload length' field"); |
| |
| </script> |